品牌:P+F/倍加福型号:LVL-A7-BG4B-E5PU-CG-EMS类型:音叉液位计测量范围:1-2m测量精度:1-1分辨率:1-1盲区:1-1压力:1-4供电电压:1-4V模拟输出:1-8Rated voltage:10 ... 35 V DCFusing:external 500 mA slowCurrent consumption:< 15 mAResidual ripple:5 V ss at 0 ... 400 HzMeasured variable:density冯工:13681942816QQ:2851708645
General specifications
Measuring method | The tuning fork is brought to its resonance frequency by means of a piezoelectric drive. If the tuning fork is covered by liquid, this frequency changes. The electronics monitor the resonance frequency and indicate whether the tuning fork is freely vibrating or is covered by liquid. |
Construction type | device with short tube |
Operating mode | MAX = maximum safety: The device keeps the electronic switch closed as long as the liquid level is below the fork. example application: overspill protection MIN = minimum safety: The device keeps the electronic switch closed as long as the fork is immersed in liquid. example application: dry running protection of pumps The electronic switch opens if the limit is reached, if a fault occurs or in the event of a power fails (quiescent current principle) |
Supply
Connection | This device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements. |
Rated voltage | 10 ... 35 V DC |
Fusing | external 500 mA slow |
Current consumption | < 15 mA |
Residual ripple | 5 V ss at 0 ... 400 Hz |
Input
Measured variable | density |
Measurement range | min. 0.7 g/cm3 |
Output
Output type | switch output |
Switching current | max. 250 mA |
Directive conformity
Electromagnetic compatibility | |
| Directive 2014/30/EU | EN 61326-1:2006 , EN 61326-2-3:2006 |
| Directive 2004/108/EC | EN 61326-1:2006 , EN 61326-2-3:2006 |
Conformity
Electromagnetic compatibility | NE 21 |
Degree of protection | IEC 60529 |
Shock resistance | EN 60068-2-27 |
Vibration resistance | EN 60068-2-64 |
Climate class | DIN EN 60068-2-38/IEC 68-2-38 |
Measurement accuracy
Reference operating conditions | - ambient temperature: 25 °C (+77 °F) - process pressure: 1 bar (14.5 psi) - fluid: water (density: approx. 1 g/cm3, viscosity: 1 mm2/s) - medium temperature: 25 °C (+77 °F) - density setting: > 0.7 g/cm3 - switching time delay: standard (0,5 s, 1 s) |
Measured value resolution | < 0.5 mm |
Measuring frequency | approx. 1100 Hz in air |
Switching point | 13 mm ± 1 mm |
Non-repeatability | ± 1 mm acc. to DIN 61298-2 |
Hysteresis | max. 3 mm |
Influence of ambient temperature | negligible |
Influence of medium temperature | -25 µm/°C |
Influence of medium pressure | -20 µm/bar |
Switching time | - 0.5 s when tuning fork is covered - 1.0 s when tuning fork is uncovered |
Switch-on delay | max. 3 s |
Operating conditions
Installation conditions | |
| Installation position | see technical information (TI) |
Ambient conditions | |
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Shock resistance | a = 300 m/s2 = 30 g, 3 planes x 2 directions x 3 shocks x 18 ms, as per test Ea |
| Vibration resistance | a(RMS) = 50 m/s2, ASD = 1.25 (m/s2)2/Hz, f = 5 to 2000 Hz, t = 3 x 2 h |
Process conditions | |
| Medium temperature | -40 ... 150 °C (-40 ... 302 °F) |
| Process pressure (static pressure) | -1 ... +40 bar (-14.5 ... +580 psi) |
| State of aggregation | liquid |
| Density | min. 0.7 g/cm3 |
| Viscosity | 1 ... 10000 mPa/s, dynamic viscosity |
| Solid contents | < ∅5 mm |
Mechanical specifications
Degree of protection | IP65 , NEMA 4X |
Connection | valve connector M16 |
Material | process connection and short tube: stainless steel 316L (1.4401/1.4435) tuning fork: stainless steel 316L housing cover and connector: PPSU |
Surface quality | Ra < 3.2 µm |
Mass | approx. 169 g |
Process connection | thread G1 acc. to ISO 228 |
Certificates and approvals
Overspill protection | see approval (ZE) |
Accessories
Designation | see technical information (TI) |